Tripp Lite SmartPro 2200VA 1920W LCD RM 2U WEBCARDLX Pre-Installed
Model: SMART2200RM2UN
Input: NEMA 5-20P (120V - 20A)
Output: (4) NEMA 5-15R, (4) NEMA 5-15/20R
Maximum Output: 2200VA / 1920W
Line-Interactive UPS - Pure Sine Wave Output
Automatic Voltage Regulation (AVR)
LCD Status & Control Display
New Batteries, Refurbished UPS
1 Year Full Replacement Warranty Included
In stock
Manufacturer: Tripp Lite
Model: Tripp Lite SmartPro 2200VA 1920W, LCD, Rackmount 2U, 120V, WEBCARDLX Network Interface
Condition: New Batteries, Refurbished UPS
Part Number: SMART2200RM2UN
Maximum Output: 1920W / 2200VA
Input: NEMA 5-20P (120V - 20A)
Output: (4) NEMA 5-15R, (4) NEMA 5-15/20R
Topology: Line-Interactive UPS with AVR
Waveform: Pure Sine Wave Output
Network Management: WEBCARDLX Pre-Installed
Battery Type: Valve-Regulated Lead-Acid (VRLA)
Battery System Voltage: 48V DC
Replacement Battery: RBC94-2U
Typical Backup Time at Half Load: 12 minutes (960W)
Typical Backup Time at Full Load: 4.5 minutes (1920W)
Warranty: 1 Year Full Replacement WarrantyÂ
Description:Â The Tripp Lite SMART2200RM2UN is a 2200VA / 1920W Line-Interactive UPS designed for servers, networking equipment, and other critical electronics. It provides pure sine wave output, Automatic Voltage Regulation (AVR), LCD monitoring, hot-swappable batteries, and a pre-installed WEBCARDLX Network Management Card for remote monitoring and management. Refurbished with new batteries and backed by a 1 Year Full Replacement Warranty.
Â
Â
Tripp Lite SmartPro 2200VA 1920W RM 120V SMART2200RM2UN - User's Manual
Â
Â
SMART2200RM2UN - Tripp Lite SmartPro 2200VAÂ Specifications:
| Main | Â | ||||
| Manufacturer | Tripp Lite | ||||
| Model | SMART2200RM2UN | ||||
| Product Series | SmartPro | ||||
| Product Type | Uninterruptible Power Supply (UPS) | ||||
| Maximum Output Capacity | 2200VA / 1920W | ||||
| Topology | Line-Interactive | ||||
| Waveform Type | Pure Sine Wave | ||||
| Nominal Voltage | 120V | ||||
| Input Phase | Single-Phase | ||||
| Form Factor | Rackmount | ||||
| Rack Height | 2U | ||||
| Automatic Voltage Regulation | Yes (AVR) | ||||
| Network Management | WEBCARDLX Pre-Installed | ||||
| Condition | Refurbished UPS with New Batteries | ||||
| Warranty | 1 Year Full Replacement Warranty | ||||
| Â | Â | ||||
| Input | Â | ||||
| Nominal Input Voltage | 120V AC | ||||
| Rated Input Current | 16A at 120V | ||||
|
UPS Input Connection Type |
|
||||
| Input Circuit Breaker | 20A | ||||
| Recommended Electrical Service | 20A, 120V | ||||
| Input Cord Length | 10 ft (3.1 m) | ||||
| Input Phase | Single-Phase | ||||
| Â | Â | ||||
| Output | Â | ||||
| Output Volt-Amp Capacity | 2200VA | ||||
| Output Capacity | 2.2kVA | ||||
| Output Watt Capacity | 1920W | ||||
| Output kW Capacity | 1.92kW | ||||
| Power Factor | 0.87 | ||||
| Nominal Output Voltage | 120V | ||||
| Supported Output Voltages | 110V / 115V / 120V | ||||
| Frequency Compatibility | 60 Hz | ||||
| Output Voltage Regulation – Line Mode | -14% / +6% | ||||
| Output Voltage Regulation – Battery Mode | ±5% | ||||
| Output Waveform – AC Mode | Pure Sine Wave | ||||
| Output Waveform – Battery Mode | Pure Sine Wave | ||||
|
Output Receptacles |
|
||||
| Load Management Receptacles | Two Switchable Single-Outlet Load Banks | ||||
| Individually Controllable Load Banks | Yes | ||||
| Outlet Protection | Battery Backup, Surge and Line Noise Protection | ||||
| Â | Â | ||||
| Batteries & Runtime | Â | ||||
| Battery Type | Valve-Regulated Lead-Acid (VRLA) | ||||
| DC System Voltage | 48V DC | ||||
| Typical Runtime at Half Load | 12 Minutes (960W) | ||||
| Typical Runtime at Full Load | 4.5 Minutes (1920W) | ||||
| Internal Replacement Battery Cartridge | RBC94-2U | ||||
| Battery Access | Front Panel Battery Access | ||||
| Battery Replacement | Hot-Swappable, User-Replaceable | ||||
| Battery Recharge Time | Less than 4.5 Hours from 10% to 90% | ||||
| Expandable Runtime | No | ||||
| Hot-Swappable Batteries | Yes | ||||
| Battery Self-Test | Yes | ||||
| Â | Â | ||||
| Voltage Regulation | Â | ||||
| Voltage Regulation | Automatic Voltage Regulation (AVR) | ||||
| AVR Input Range | 83–145V | ||||
| Overvoltage Correction | Input 127–145V Reduced by 12% | ||||
| Undervoltage Correction | Input 96–108V Boosted by 12% | ||||
| Severe Undervoltage Correction | Input 83–95V Boosted by 24% | ||||
| Â | Â | ||||
| User Interface & Controls | Â | ||||
| Display | Multifunction Front-Panel LCD | ||||
| LCD Monitoring | Input Voltage, Output Voltage, Estimated Runtime, Load %, Load Wattage, kWh/Day and Battery Capacity | ||||
| LCD Controls | Power, Mode and Mute/Enter | ||||
| AVR Event Monitoring | Yes | ||||
| Battery Event Monitoring | Yes | ||||
| Battery Capacity Monitoring | Yes | ||||
| Estimated Runtime Display | Yes | ||||
| Alarm Control | Enable / Disable | ||||
| Audible Alarm | Startup, Power Failure, Low Battery, Overload, UPS Fault and Remote Shutdown | ||||
| Â | Â | ||||
| Surge & Noise Protection | Â | ||||
| Surge Energy Rating | 570 Joules | ||||
| Surge Response Time | Instantaneous | ||||
| EMI / RFI Noise Suppression | Yes | ||||
| Â | Â | ||||
| Communications & Management | Â | ||||
| Network Management Card | WEBCARDLX | ||||
| Network Management Card Installation | Pre-Installed | ||||
| Network Monitoring | Yes | ||||
| Network Connection | RJ45 Ethernet | ||||
| Remote UPS Management | Yes | ||||
| SNMP Compatibility | SNMP v1 / v2c / v3 | ||||
| USB Interface | Yes | ||||
| Serial Interface | DB9 RS-232 | ||||
| EPO | Yes | ||||
| EPO Interface | RJ11 | ||||
| PowerAlert Software | Supported | ||||
| WatchDog Compatibility | Yes | ||||
| Network UPS Tools (NUT) Compatibility | Yes | ||||
| Communications Cables | Micro-USB, USB and DB9 | ||||
| Remote Outlet Control | Supported | ||||
| Remote Reboot | Supported Through Controllable Load Banks | ||||
| Network Status Indicators | Link / Activity and Network Speed LEDs | ||||
| Â | Â | ||||
| Physical | Â | ||||
| Primary Form Factor | Rackmount | ||||
| Rack Height | 2U | ||||
| Housing Material | Steel | ||||
| Cooling Method | Fan | ||||
| Height | 3.43 in (87 mm) | ||||
| Width | 17.32 in (440 mm) | ||||
| Depth | 19.46 in (494 mm) | ||||
| Net Weight | 57.6 lb (26.13 kg) | ||||
| Minimum Required Rack Depth | 24.5 in (62.23 cm) | ||||
| Optional 2-Post Rackmount | Supported with 2POSTRMKITWM | ||||
| Optional Tower Installation | Supported with 2-9USTAND | ||||
| Optional Wall Mounting | Supported with 2POSTRMKITWM | ||||
| Â | Â | ||||
| Environmental | Â | ||||
| Operating Temperature | 32–104°F (0–40°C) | ||||
| Storage Temperature | 5–122°F (-15–50°C) | ||||
| Relative Humidity | 0–95%, Non-Condensing | ||||
| AC Mode Efficiency at Full Load | 96% | ||||
| AC Mode Heat Dissipation | 306 BTU/hr at Full Load | ||||
| Battery Mode Heat Dissipation | 1157 BTU/hr at Full Load | ||||
| Audible Noise | 45 dBA Maximum at 1 m | ||||
| Â | Â | ||||
| Additional Features | Â | ||||
| Cold Start | Yes | ||||
| Automatic Battery Charging | Yes | ||||
| LCD Configurable Alarm | Yes | ||||
| LCD Brightness Control | Yes | ||||
| Self-Test | Yes | ||||
| Remote Shutdown | Supported | ||||
| Emergency Power Off | Supported | ||||
| Application | Servers, Network Equipment, Storage Systems, Telecommunications and Other Critical Electronics |