Tripp Lite SmartPro 500VA 300W RM 1U
Model: SMART500RT1U
Input: NEMA 5-15P (120V - 15A)
Output: (6) NEMA 5-15R
Line-Interactive UPS - Sinewave / PWM Sinewave Output
Automatic Voltage Regulation (AVR)
USB, RS-232 & EPO Connectivity
Optional Network Management Card
Remote Reboot & Outlet Control via PowerAlert
New Batteries, Refurbished UPS
1 Year Warranty Included
Back Order
Manufacturer: Tripp Lite
Model: Tripp Lite Smart-Pro UPS 500VA 300W, RM, 1U, 120V
Condition: New Batteries, Refurbished UPS
Part Number: SMART500RT1U
Maximum output: 300W / 500VA
Typical backup time at half load: 14.6 minutes (150 Watts)
Typical backup time at full load: 3.2 minutes (300 Watts)
Warranty: 1 year full replacement warranty
Description: The Tripp Lite SMART500RT1U is a compact 500VA / 300W line-interactive UPS designed for rackmount servers, networking equipment, telecommunications systems, and other critical electronics. Its low-profile 1U design supports both 2-post and 4-post rack installations as well as tower placement. The UPS provides 120V power through (6) NEMA 5-15R outlets, Automatic Voltage Regulation (AVR), USB and RS-232 communications, EPO connectivity, and an accessory slot for optional remote network management. It also supports remote outlet control through Tripp Lite PowerAlert software. Refurbished with new batteries and backed by a 1 Year Full Replacement Warranty. The manual specifically identifies SMART500RT1U as a SmartPro 1U intelligent line-interactive UPS
Â
Tripp Lite SmartOnline 500VA 300W RM 120V SMART500RT1U - User Manual
Â
Â
SMART500RT1U - Tripp Lite SmartOnline 500VAÂ Specifications:
| Main | Â | Â |
| Manufacturer | Tripp Lite | Â |
| Product Family | SmartPro | Â |
| Model / Part Number | SMART500RT1U | Â |
| Product Type | UPS Battery Backup | Â |
| UPS Topology | Line-Interactive | Â |
| Maximum Output | 300W / 500VA | Â |
| Power Factor | 0.6 | Â |
| Nominal Input Voltage | 120V AC | Â |
| Nominal Output Voltage | 120V AC | Â |
| Input Phase | Single-Phase | Â |
| Form Factor | Rackmount / Tower | Â |
| Rack Height | 1U | Â |
| Condition | New Batteries, Refurbished UPS | Â |
| Â | Â | Â |
| Input | Â | Â |
| Nominal Input Voltage | 120V AC | Â |
| Input Voltage Range | 90–139V AC |  |
| UPS Input Connection | NEMA 5-15P | |
| Input Cord Type | Attached power cord | Â |
| Input Cord Length | 10 ft (3.1 m) | Â |
| Rated Input Current at Maximum Load | 10A | Â |
| Input Circuit Breaker | 10A | Â |
| Recommended Electrical Service | 15A / 120V | Â |
| Input Phase | Single-Phase | Â |
| Â | Â | Â |
| Output | Â | Â |
| Output VA Capacity | 500VA | Â |
| Output Watt Capacity | 300W | Â |
| Output Power Factor | 0.6 | Â |
| Nominal Output Voltage | 120V | Â |
| Output Current at Rated Load | 4.2A at 120V | Â |
| Output Frequency | 60 Hz | Â |
| Frequency Regulation | ±0.05Hz when input frequency exceeds ±5Hz of nominal |  |
| Output Voltage Regulation - Line Mode | -14% / +16% | Â |
| Output Voltage Regulation - Battery Mode | ±5% |  |
| Output Waveform - Line Mode | Sine Wave | Â |
| Output Waveform - Battery Mode | PWM Sine Wave | Â |
| Total Output Receptacles | (6) NEMA 5-15R | Â |
| Battery Backup / UPS Outlets | (5) NEMA 5-15R | |
| Surge-Only Outlet | (1) NEMA 5-15R | |
| Load Management Receptacle | (1) switchable NEMA 5-15R load bank | Â |
| Individually Controllable Load Banks | Yes | Â |
| Remote Outlet ON/OFF Control | Yes, for switchable outlet using PowerAlert | Â |
| Remote Equipment Reboot | Yes, through switchable outlet control | Â |
| Line-Mode Overload Capacity | 120% for 5 minutes | Â |
| Battery-Mode Overload Capacity | 120% for 5 seconds | Â |
| Â | Â | Â |
| Batteries & Runtime | Â | Â |
| Battery Type | Valve-Regulated Lead-Acid (VRLA) | Â |
| DC System Voltage | 12V DC | Â |
| Typical Backup Time at Half Load | 14.6 minutes at 150W | Â |
| Typical Backup Time at Full Load | 3.2 minutes at 300W | Â |
| Battery Recharge Rate | Less than 12 hours to 90% | Â |
| Initial Full Runtime Charge | Approximately 24 hours before maximum battery runtime is available | Â |
| Battery Access | Battery access door | Â |
| Hot-Swappable Battery | Yes | Â |
| User-Replaceable Battery | Yes | Â |
| Replacement Battery - Series AG-03AA | RBC12V-1U | Â |
| Replacement Battery - Earlier Versions | RBC62-1U | Â |
| External Battery Pack Support | No | Â |
| Expandable Runtime | No | Â |
| Â | Â | Â |
| Voltage Regulation | Â | Â |
| Automatic Voltage Regulation (AVR) | Yes | Â |
| AVR Operating Range | 90–139V AC |  |
| AVR Low-Voltage Operation | Maintains line-power operation with input voltage as low as approximately 90V AC | Â |
| Undervoltage Correction | Input voltages between approximately 90V and 105V are boosted by 14% | Â |
| Battery Conservation | AVR corrects applicable voltage fluctuations without switching to battery power | Â |
| Â | Â | Â |
| Communications & Management | Â | Â |
| Network Management | Optional | Â |
| Network Management Card Included | No | Â |
| Network Management Slot | Accessory slot for optional SNMP / Web network management card | Â |
| Compatible Network Management Cards | SNMPWEBCARD55, WEBCARDLX | Â |
| USB Communication | Yes | Â |
| USB Interface | HID-enabled | Â |
| Serial Communication | DB9 RS-232 | Â |
| EPO Port | Yes | Â |
| Local UPS Monitoring | Yes | Â |
| Local Management Interfaces | USB and DB9 RS-232 | Â |
| Power Management Software | Tripp Lite PowerAlert | Â |
| UPS Operating Condition Monitoring | Yes | Â |
| AC Line Power Monitoring | Yes | Â |
| Automatic Computer Shutdown | Supported through PowerAlert | Â |
| Remote Outlet Control | Yes, for controllable outlet | Â |
| Remote Equipment Reboot | Yes | Â |
| WatchDog Compatibility | Yes | Â |
| WatchDog Application Restart | Supported | Â |
| WatchDog Operating System Restart | Supported | Â |
| WatchDog Hard-Reboot | Supported | Â |
| Emergency Power Off | Supported through EPO port | Â |
| Â | Â | Â |
| User Interface, Alerts & Controls | Â | Â |
| User Interface | LED status and control panel | Â |
| Control Switches | (2) | Â |
| ON/OFF/STANDBY Control | Yes | Â |
| MUTE/TEST Control | Yes | Â |
| Alarm Cancel | Yes | Â |
| Self-Test | Yes | Â |
| Cold Start | Yes | Â |
| LED Indicators | (5) | Â |
| Power / Line Status Indicator | Yes | Â |
| Voltage Correction Indicator | Yes | Â |
| Output Load Level Indicator | Yes | Â |
| Battery Charge Indicator | Yes | Â |
| Battery Warning Indicator | Yes | Â |
| Load Level Indication | Green / Yellow / Red indication for light, medium and overload conditions | Â |
| Battery Charge Indication | Green / Yellow / Red indication of approximate battery charge | Â |
| Audible Alarm | Yes | Â |
| Power Failure Alarm | Yes | Â |
| Overload Alarm | Yes | Â |
| Low-Battery Alarm | Yes | Â |
| Battery Replacement Warning | Yes | Â |
| Alarm Silencing | Yes | Â |
| Â | Â | Â |
| Power Management Features | Â | Â |
| Switchable Outlet Bank | Yes | Â |
| Unswitched Outlets | Yes | Â |
| Software-Controlled Outlet Switching | Yes | Â |
| Remote Power Cycling | Yes | Â |
| Connected Equipment Reboot | Yes | Â |
| Automatic Shutdown Support | Yes | Â |
| Power Failure Monitoring | Yes | Â |
| UPS Status Monitoring | Yes | Â |
| Â | Â | Â |
| Surge Protection & Filtering | Â | Â |
| AC Surge Suppression | Yes | Â |
| Surge Energy Rating | 567 Joules | Â |
| Surge Suppression Response Time | Instantaneous | Â |
| EMI / RFI AC Noise Suppression | Yes | Â |
| Line Noise Filtering | Yes | Â |
| Â | Â | Â |
| Physical | Â | Â |
| Primary Form Factor | Rackmount / Tower | Â |
| Rack Height | 1U | Â |
| Rack Standard | 19-inch | Â |
| 2-Post Rack Installation | Supported | Â |
| 2-Post Front Mount Installation | Supported | Â |
| 4-Post Rack Installation | Supported | Â |
| Tower Installation | Supported | Â |
| Mounting Brackets | Supported | Â |
| Minimum Required Rack Depth | 14.3 in (36.32 cm) | Â |
| UPS Height | 1.73 in (4.39 cm / 44 mm) | Â |
| UPS Width | 17.32 in (43.99 cm / 440 mm) | Â |
| UPS Depth | 11.26 in (28.60 cm / 286 mm) | Â |
| UPS Weight | 15.84 lb (7.18 kg) | Â |
| Housing Material | Steel | Â |
| Â | Â | Â |
| Environmental | Â | Â |
| Operating Temperature | 32°F to 104°F (0°C to 40°C) |  |
| Storage Temperature | 5°F to 122°F (-15°C to 50°C) |  |
| Relative Humidity | 0–95%, non-condensing |  |
| Maximum Operating Elevation | 6561 ft (2000 m) above sea level | Â |
| Audible Noise | 45 dBA maximum at 1 meter | Â |
| Heat Dissipation - AC Mode, Full Load | 48 BTU/hr | Â |
| AC Mode Efficiency at 100% Load | 97% | Â |
| Â | Â | Â |
| Packaging | Â | Â |
| Shipping Height | 4.20 in (10.67 cm) | Â |
| Shipping Width | 15.70 in (39.88 cm) | Â |
| Shipping Depth | 21.30 in (54.10 cm) | Â |
| Shipping Weight | 19.12 lb (8.67 kg) | Â |
| Â | Â | Â |
| General | Â | Â |
| Recommended Application | Servers, networking equipment, telecommunications and other critical electronic equipment | Â |
| Battery Backup | Yes | Â |
| Surge Protection | Yes | Â |
| Automatic Voltage Regulation | Yes | Â |
| Rack / Tower Convertible | Yes | Â |
| Remote Management Capability | Yes, through local communications or optional network management card | Â |
| Generator Compatibility | Compatible with properly regulated, computer-grade AC generators | Â |
| Â | Â | Â |
| Condition & Warranty | Â | Â |
| Condition | Refurbished UPS | Â |
| Batteries | New Batteries | Â |
| Warranty | 1 Year Full Replacement Warranty | Â |