Tripp Lite Smart-Pro 500VA 300W RM 1U
Model: SMART500RT1U
Input: NEMA 5-15P (120V - 15A)
Output: (6) NEMA 5-15R
Line-Interactive UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included
In stock
Manufacturer: Tripp Lite
Model: Tripp Lite Smart-Pro UPS 500VA 300W, RM, 1U, 120V
Condition: New batteries, refurbished UPS
Part Number: SMART500RT1U
Maximum output: 300W / 500VA
Typical backup time at half load: 14.6 minutes (150 Watts)
Typical backup time at full load: 3.2 minutes (300 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartOnline 500VA 300W RM 120V SMART500RT1U User Manual
SMART500RT1U - Tripp Lite SmartOnline 500VAÂ Specifications:
Input:
|
Rated input current (Maximum Load) |
10A |
||
|
Nominal Input Voltage(s) Supported |
120V AC |
||
|
UPS Input Connection Type |
|
||
|
Input Circuit Breakers |
10A |
||
|
UPS Input Cord Length (ft.) |
10 |
||
|
UPS Input Cord Length (m) |
3.1 |
||
|
Recommended Electrical Service |
15A 120V |
||
|
Input Phase |
Single-Phase |
Output:
|
Output Volt Amp Capacity (VA) |
500 |
||||
|
Output Watt Capacity (Watts) |
300 |
||||
|
Output kW Capacity (kW) |
2.4 |
||||
|
Output Capacity Details |
4.2A @ 120V. (LINE MODE) 120% @ 5 minutes; (BATTERY MODE) 120% @ 5 seconds |
||||
|
Power Factor |
0.6 |
||||
|
Nominal Voltage Details |
120V sinusoidal in line mode and 120V PWM in battery mode |
||||
|
Frequency Compatibility |
60 Hz |
||||
|
Frequency Compatibility Details |
Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. |
||||
|
Output Voltage Regulation (Line Mode) |
-14%, +16% |
||||
|
Output Voltage Regulation (Battery Mode) |
+/- 5% |
||||
|
UPS Output Receptacles (Surge Suppression Only) |
5 UPS outlets, 1 surge-only outlet |
||||
|
Load Management Receptacles |
One switchable single-outlet 5-15R load bank |
||||
|
Output Circuit Breakers |
15A branch rated (x2) - each breaker protects 4 outlets, L5-30R is unbreakered |
||||
|
Output AC Waveform (AC Mode) |
Sine wave |
||||
|
Output AC Waveform (Battery Mode) |
PWM sine wave |
||||
|
Nominal Output Voltage(s) Supported |
120V |
||||
|
Output Receptacles |
|
||||
|
Individually Controllable Load Banks |
Yes |
Battery:
|
Battery Type |
Valve Regulated Lead Acid (VRLA) |
|
Full Load Runtime (min.) |
3 min. (300w) |
|
Half Load Runtime (min.) |
14 min. (150w) |
|
Expandable Battery Runtime |
Supports extended runtime with optional external battery packs |
|
Expandable Runtime |
No |
|
DC System Voltage (VDC) |
12 |
|
Battery Recharge Rate (Included Batteries) |
Less than 12 hours to 90% |
|
Battery Access |
Battery access door |
|
Internal UPS Replacement Battery Cartridge |
IMPORTANT BATTERY REPLACEMENT INFORMATION > Use Tripp Lite RBC12V-1U replacement battery for SMART500RT1U models with Series Number AG-03AA listed on the UPS nameplate (sold starting in 2021); For all prior versions of SMART500RT1U, use Tripp Lite  RBC62-1U replacement battery; Contact Tripp Lite customer service for additional information |
|
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Voltage Regulation:
|
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 90 (±5%). Input voltage range of 90 to 139 |
|
Undervoltage Correction |
Input voltages between 90 and 105 (±5%) are boosted by 14% |
User Interface, Alerts & Controls:
|
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
|
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch |
|
Audible Alarm |
Audible alarm indicates power-failure, overload and low-battery conditions |
|
LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
Surge / Noise Suppression:
|
UPS AC Suppression Joule Rating |
567 J |
|
UPS AC Suppression Response Time |
Instantaneous |
|
EMI / RFI AC Noise Suppression |
Yes |
Physical:
|
Primary Form Factor |
Rackmount; Tower
|
|
Included Mounting Accessory Description |
Included mounting brackets provide front-rail installation in 2 or 4 post racks, plus upright tower configurations
|
|
Installation Form Factors Supported with Included Accessories |
2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount; Tower
|
|
Minimum Required Rack Depth (cm) |
36.32
|
|
Minimum Required Rack Depth (inches) |
14.3
|
|
Primary UPS Depth (mm) |
286
|
|
Primary UPS Height (mm) |
44
|
|
Primary UPS Width (mm) |
440 |
|
Rack Height |
1U |
|
Shipping Dimensions (hwd / cm) |
10.67 x 39.88 x 54.10 |
|
Shipping Dimensions (hwd / in.) |
4.20 x 15.70 x 21.30 |
|
Shipping Weight (kg) |
8.67 |
|
Shipping Weight (lbs.) |
19.12 |
|
UPS Housing Material |
Steel |
|
UPS Power Module Dimensions (hwd, cm) |
4.39 x 43.99 x 28.60 |
|
UPS Power Module Dimensions (hwd, in.) |
1.73 x 17.32 x 11.26 |
|
UPS Power Module Weight (kg) |
7.18 |
|
UPS Power Module Weight (lbs.) |
15.84 |
Environmental:
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
|
Relative Humidity |
0 to 95%, non-condensing |
|
AC Mode BTU / Hr. (Full Load) |
48 |
|
AC Mode Efficiency Rating (100% Load) |
97% |
|
AC Economy Mode Efficiency Rating (100% Load) |
0.97 |
|
Operating Elevation (ft.) |
6561 ft. (2000 m) above sea level |
|
Audible Noise |
45 dBA maximum, front side 1m |
Communications:
|
Network Management Cards |
Compatible with: SNMPWEBCARD55, WEBCARDLX. |
|
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
|
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert |
|
Communications Cable |
USB and DB9 cabling |
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
Network Management Card Description |
Optional Network management card |
|
Communications Interface |
DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |