Tripp Lite SmartPro UPS 1000VA 700W 120V Output: (6)5-15R SMART1000RM2U - Refurbished

Tripp Lite SmartPro 1000VA 700W RM 2U 120V
Model: SMART1000RM2U
Input: NEMA 5-15P (120V - 15A)
Output: (6) NEMA 5-15R
Line-Interactive UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included

In stock

Love Manufacturer: Tripp Lite
Model:
Tripp Lite SmartPro UPS 1000VA 700W, RM, 2U, 15A, 120V
Condition:
New batteries, refurbished UPS
Part Number:
SMART1000RM2U

Maximum output: 700W / 1000VA
Typical backup time
at half load:15 minutes (400 Watts)
Typical backup time
at full load: 5.3 minutes (700 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartPro 1000VA 700W RM 120V SMART1000RM2U Manual

 


SMART1000RM2U - Tripp Lite SmartPro 1000VA Specifications:

Input:

Rated input current (Maximum Load)

6.8A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

NEMA 5-15P

Input Circuit Breakers

15A

UPS Input Cord Length (ft.)

10

UPS Input Cord Length (m)

3.0

Recommended Electrical Service

15A 120V

Input Phase

Single-Phase

Output:

Output Volt Amp Capacity (VA)

1000

Output Capacity (kVA)

1.0

Output Watt Capacity (Watts)

700

Power Factor

0.8

Nominal Voltage Details

120v nominal output in battery mode

Frequency Compatibility

60 Hz

Output Voltage Regulation (Line Mode)

-21%, +8%

Output Voltage Regulation (Battery Mode)

+/- 5%

Load Management Receptacles

Two switchable two-outlet 5-15R load banks

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

110V; 115V; 120V

Output Receptacles

(6) NEMA 5-15R

Individually Controllable Load Banks

 Yes


Battery:

Battery Type

Valve Regulated Lead Acid (VRLA)

Full Load Runtime (min.)

9 minutes (700 watts)

Half Load Runtime (min.)

21 min. (350w)

Expandable Runtime

No

DC System Voltage (VDC)

24

Battery Recharge Rate (Included Batteries)

2–4 hours to 90% (typical)

Internal UPS Replacement Battery Cartridge

RBC24S (Tripp Lite replacement cartridge for SMART1000RM2U)

Battery Access

Battery access door allows hot-swap replacement without powering down connected equipment

Battery Replacement Description

Hot-swappable, user replaceable batteries


Voltage Regulation:

Voltage Regulation Description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147

Overvoltage Correction

Input voltages between 128 and 147 are reduced by 12%

Undervoltage Correction

Input voltages between 83 and 107 are boosted by 14%


User Interface, Alerts & Controls:

Front Panel 

The SMART1000RM2U does not include an LCD display. Instead, it features five front panel LEDs that provide at-a-glance notification of UPS and line power status — including Power, Battery Charge, Output Load Level, and Battery Warning indicators.

Switches

Includes two front panel mounted push-button switches for system enable, self-test, and alarm cancel functions

Alarm Cancel Operation

The audible alarm can be silenced temporarily using the alarm cancel switch located on the front panel

Audible Alarm

Provides three audible alarm modes: 4 short beeps every 10 seconds (power failure), continuous short beeps (overload), and continuous tone (low battery)


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

570

UPS AC Suppression Response Time

Instantaneous

EMI / RFI AC Noise Suppression

Yes


Physical:

Primary Form Factor

Rackmount

Cooling Method

Fan

Rail kit not included

No rail kit included (options listed below)

Installation Form Factors Supported with Included Accessories

4 post 19 inch rackmount

Installation Form Factors Supported with Optional Accessories (NOT INCLUDED)

2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2- 9USTAND ); Wallmount ( 2POSTRMKITWM )

Minimum Required Rack Depth (cm)

39.37

Minimum Required Rack Depth (inches)

15.5

Optional Mounting Accessory Notes

Optional  2-9USTAND  enables upright tower UPS placement;  2POSTRMKITWM  enables wall-mount and 2-post rackmount installation;  4POSTRAILKITWM  enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  UPSHDEARKIT  enables installation in 2 or 4-post racks using front vertical rails only, without rear support

Primary UPS Depth (mm)

318

Primary UPS Height (mm)

88

Primary UPS Width (mm)

441

Rack Height

2U

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

8.76 x 44.07 x 31.75

UPS Power Module Dimensions (hwd, in.)

3.45 x 17.35 x 12.5

UPS Power Module Weight (kg)

16.06

UPS Power Module Weight (lbs.)

35.4

 


Environmental:

Operating Temperature Range

+32 to +104°F / 0 to +40°C

Storage Temperature Range

+5 to +122°F / -15 to +50°C

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

Not specified in the official datasheet

Battery Mode BTU / Hr. (Full Load)

Not specified in the official datasheet

AC Mode Efficiency Rating (100% Load)

95%

Audible Noise

45 dBA max (front side, 1 meter)


Communications:

Network Management Cards (OPTIONAL, NOT INCLUDED)

SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert

Communications Cable

USB and DB9 cabling

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Network UPS Tools Compatibility

NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite

Network Management Card Description

Network management card optional

Communications Interface

DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)