Tripp Lite Smart Pro UPS 1500VA 1000W RM 2U 120V Output:(8)5-15R, SMC15002URM - Refurbished

Tripp Lite SmartPro UPS 1500VA 1000W RM 2U
Model: SMC15002URM
Input: NEMA 5-15P (120V - 15A)
Output: (8) NEMA 5-15R
Line-Interactive UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included

Back Order

Manufacturer: Tripp Lite
Model:
Tripp Lite SmartPro UPS 1500VA 1000W, RM, 2U, 15A 120V, New Batteries, Refurbished UPS
Condition:
New batteries, refurbished UPS
Part Number:
SMC15002URM

Maximum output: 1000W / 1500VA
Typical backup time
at half load: 17.7 minutes (500 Watts)
Typical backup time
at full load: 6.5 minutes (1000 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartPro UPS 1500VA 1000W RM 2U SMC15002URM Manual

 


SMC15002URM - Tripp Lite SmartPro UPS Specifications:

Output:

Output Volt Amp Capacity (VA)

1500

Output kVA Capacity (kVA)

1.5

Output Watt Capacity (Watts)

1000

Output kW Capacity (kW)

1.0

Nominal Voltage Details

120v nominal output in battery mode

Frequency Compatibility

60 Hz

Output Voltage Regulation (Line Mode)

-21%, +8%

Output Voltage Regulation (Battery Mode)

+/- 5%

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

110V; 115V; 120V

Output Receptacles

(8) NEMA 5-15R

Individually Controllable Load Banks

No


Input:

Rated input current (Maximum Load)

12A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

NEMA 5-15P

Input Circuit Breakers

15A

UPS Input Cord Length (ft.)

10

UPS Input Cord Length (m)

3.1

Recommended Electrical Service

15A 120V

Input Phase

Single-Phase


Battery:

Full Load Runtime (min.)

6.5 min. (1000W)

Half Load Runtime (min.)

17.7 min. (500W)

DC System Voltage (VDC)

36

Battery Recharge Rate (Included Batteries)

Less than 4.5 hours from 10% to 90% (typical, full load discharge)

Internal UPS Replacement Battery Cartridge

RBC93-2U

Battery Access

Front panel battery access door

Battery Replacement Description

Hot-swappable, user replaceable batteries

Expandable Runtime

No


Voltage Regulation:

Voltage Regulation Description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147

Overvoltage Correction

Input voltages between 128 and 147 are reduced by 12%

Undervoltage Correction

Input voltages between 83 and 107 are boosted by 14%


User Interface, Alerts & Controls:

Front Panel LCD Display

Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)

Switches

3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions

Alarm Cancel Operation

Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available

Audible Alarm

Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

570

UPS AC Suppression Response Time

Instantaneous

EMI / RFI AC Noise Suppression

Yes


Physical:

Cooling Method

Fan

Included Mounting Accessory Description

Includes UPSHDEARKIT for 2 point front-mount and 2 point center-mount rackmount installation in 2 and 4 post racks, plus wallmount installation; For additional stability in 4 post racks, consider optional 4 post mounting accessories 4POSTRAILKIT and 4POSTRAILKITWM

Installation Form Factors Supported with Included Accessories

2 post 19 inch rackmount; 4 post 19 inch rackmount

Installation Form Factors Supported with Optional Accessories

4 post rackmount full-depth ( 4POSTRAILKIT ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )

Minimum Required Rack Depth (cm)

41.78

Minimum Required Rack Depth (inches)

16.45

Optional Mounting Accessory Notes

Optional 2-9USTAND enables upright tower UPS placement; 4POSTRAILKIT enables installation in 4-post standard depth racks from 20.5 to 36 inches (521 to 914mm); 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm)

Primary Form Factor

Rackmount

Primary UPS Depth (mm)

342

Primary UPS Height (mm)

88

Primary UPS Width (mm)

439

Rack Height

2U

Shipping Dimensions (hwd / cm)

22.10 x 50.80 x 59.44

Shipping Dimensions (hwd / in.)

8.70 x 20.00 x 23.40

Shipping Weight (kg)

23.95

Shipping Weight (lbs.)

52.80

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

8.76 x 43.94 x 34.16

UPS Power Module Dimensions (hwd, in.)

3.45 x 17.3 x 13.45

UPS Power Module Weight (kg)

21.09

UPS Power Module Weight (lbs.)

46.5


Communications:

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert

Communications Cable

USB cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Network UPS Tools Compatibility

NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite

Communications Interface

DB9 Serial; EPO (emergency power off); USB


Line / Battery Transfer:

Transfer Time

5 milliseconds (AC to battery), 1 milliseconds (Battery to AC)

Low Voltage Transfer to Battery Power (Setpoint)

83

High Voltage Transfer to Battery Power (Setpoint)

147


Special Features:

Grounding Lug

Back panel grounding lug

Cold Start (Startup in Battery Mode During a Power Failure)

Cold-start operation supported

High Availability UPS Features

Hot swappable batteries