Tripp Lite SmartPro UPS 1500VA 1440W RM 2U 120V
Model: SMART1500CRMXL
Input: NEMA 5-15P (120V - 15A)
Output: (8) NEMA 5-15R
Line-Interactive UPS - Pure Sinewave Output
Extended Runtime - External Battery Pack Compatible
Optional Network Management Card
New Batteries, Refurbished UPS
1 Year Warranty Included
Back Order
Manufacturer: Tripp Lite
Model: Tripp Lite SmartPro UPS 1500VA 1440W, RM, 2U, 120V
Condition: New Batteries, Refurbished UPS
Part Number: SMART1500CRMXL
Maximum output: 1440W / 1500VA
Typical backup time at half load: 14 minutes (720 Watts)
Typical backup time at full load: 6 minutes (1440 Watts)
Input: NEMA 5-15P, 120V, 15A Electrical Service
Output: (8) NEMA 5-15R
Topology: Line-Interactive
Output Waveform: Pure Sine Wave on Battery
Extended Runtime: Yes – Supports External Battery Packs
Compatible External Battery Packs: BP48V24-2U (Limit 1), BP48V60RT-3U (Multi-Pack), BP48V27-2US (Multi-Pack)
Load Management: (3) Individually Controllable / Switchable NEMA 5-15R Load Banks
Network Management: Optional Network Management Card
Compatible Network Cards: WEBCARDLXE; legacy WEBCARDLX / SNMPWEBCARD support is also documented
Warranty: 1 Year Full Replacement Warranty
Description: The Tripp Lite SMART1500CRMXL is a 1500VA / 1440W line-interactive 2U rackmount UPS featuring pure sine wave battery output, AVR, expandable runtime, and three remotely switchable load banks. It supports optional network management for remote monitoring and control and includes USB, DB9 serial, and EPO connectivity. Refurbished with new batteries and backed by a 1 Year Full Replacement Warranty.
Â
Â
Tripp Lite SmartPro 1500VA 1440W RM 2U 120V SMART1500CRMXL - User Manual
Â
Â
Â
SMART1500CRMXL - Tripp Lite SmartPro 1500VAÂ Specifications:
| Main | Â | ||
| Manufacturer | Tripp Lite by Eaton | ||
| Product Family | SmartPro | ||
| Model / Part Number | SMART1500CRMXL | ||
| Product Type | Uninterruptible Power Supply (UPS) | ||
| Rated Power | 1500VA / 1440W | ||
| Output Power Factor | 1.0 | ||
| Topology | Line-Interactive | ||
| Output Waveform – AC Mode | Sine Wave | ||
| Output Waveform – Battery Mode | Pure Sine Wave | ||
| Form Factor | Rackmount | ||
| Rack Height | 2U | ||
| Nominal Voltage | 120V AC | ||
| Input Phase | Single-Phase | ||
| Extended Runtime | Yes | ||
| Â | Â | ||
| Input | Â | ||
| Nominal Input Voltage | 120V AC | ||
|
UPS Input Connection Type |
|
||
| Rated Input Current at Maximum Load | 12A | ||
| Input Circuit Breaker | 15A | ||
| Recommended Electrical Service | 15A, 120V | ||
| Input Phase | Single-Phase | ||
| Input Cord Length | 10 ft (3.1 m) | ||
| AVR Input Range | 83–145V | ||
| Low Voltage Transfer to Battery | 83V | ||
| High Voltage Transfer to Battery | 145V | ||
| Â | Â | ||
| Output | Â | ||
| Output Capacity | 1500VA / 1.5kVA | ||
| Output Power | 1440W / 1.44kW | ||
| Output Power Factor | 1.0 | ||
| Nominal Output Voltage | 120V | ||
| Supported Output Voltages | 110V / 115V / 120V | ||
|
Output Receptacles |
|
||
| Output Frequency | 60 Hz | ||
| AC Mode Waveform | Sine Wave | ||
| Battery Mode Waveform | Pure Sine Wave | ||
| Output Voltage Regulation – Line Mode | -14%, +8% | ||
| Output Voltage Regulation – Battery Mode | ±5% | ||
| Load Management Receptacles | (3) Switchable Single-Outlet NEMA 5-15R Load Banks | ||
| Individually Controllable Load Banks | Yes | ||
| Transfer Time | 5.5 ms | ||
| Â | Â | ||
| Batteries & Runtime | Â | ||
| Battery Type | Valve Regulated Lead Acid (VRLA) | ||
| DC System Voltage | 48V DC | ||
| Replacement Battery Cartridge | RBC94-2U | ||
| Battery Replacement | Hot-Swappable, User-Replaceable | ||
| Battery Access | Front-Panel Battery Access Door | ||
| Typical Recharge Time | Less than 3 Hours from 10% to 90% | ||
| Typical Backup Time at Half Load | 14 Minutes (720W) | ||
| Typical Backup Time at Full Load | 6 Minutes (1440W) | ||
| Expandable Runtime | Yes | ||
| External Battery Pack | BP48V24-2U – Limit 1 | ||
| Additional External Battery Pack | BP48V60RT-3U – Multi-Pack Compatible | ||
| Additional External Battery Pack | BP48V27-2US – Multi-Pack Compatible | ||
| New Batteries | Yes – Installed | ||
| Â | Â | ||
| Voltage Regulation | Â | ||
| Automatic Voltage Regulation (AVR) | Yes | ||
| AVR Operating Range | 83–145V | ||
| Overvoltage Correction | 127–145V Reduced by 12% | ||
| Undervoltage Correction | 96–108V Boosted by 12% | ||
| Severe Undervoltage Correction | 83–95V Boosted by 24% | ||
| Battery Conservation | AVR Corrects Voltage Without Using Battery Power | ||
| Â | Â | ||
| Communications & Management | Â | ||
| Network Management Card Included | No | ||
| Network Management | Optional | ||
| Network Management Slot | SNMP/Web Interface Slot | ||
| Current Network Management Card | WEBCARDLXE | ||
| Legacy Compatible Network Cards | WEBCARDLX, SNMPWEBCARD | ||
| Network Monitoring | Detailed UPS & Site Power Monitoring with Compatible Network Card | ||
| Remote UPS Monitoring | Supported with Compatible Network Card | ||
| Remote UPS Management | Supported with Compatible Network Card | ||
| Remote Reboot | Supported with Compatible Network Card | ||
| Remote Load Control | Supported through Switchable Load Banks | ||
| Auto Probe Monitoring & Reboot | Supported with WEBCARDLX and Required Firmware | ||
| USB Port | Yes – HID Enabled | ||
| Serial Port | DB9 Serial | ||
| EPO Port | Yes – Emergency Power Off | ||
| Communications Interface | DB9 Serial, USB HID, EPO & SNMP/Web Interface Slot | ||
| Communications Cables | USB & DB9 Cables Included | ||
| PowerAlert Software | Supported | ||
| Local UPS Monitoring | Supported through USB / Serial with PowerAlert | ||
| WatchDog Compatibility | Yes | ||
| OS / Application Restart | Supported through WatchDog | ||
| Hard-Reboot Restart | Supported through WatchDog | ||
| Â | Â | ||
| User Interface, Alerts & Controls | Â | ||
| Front Panel | LED Status Interface | ||
| LED Indicators | 5 | ||
| Line Power Indicator | Yes | ||
| Battery Power Indicator | Yes | ||
| Overload Indicator | Yes | ||
| Voltage Regulation Indicator | Yes | ||
| Low / Replace Battery Indicator | Yes | ||
| Control Switches | (2) | ||
| Self-Test Control | Yes | ||
| Alarm Cancel | Yes | ||
| Audible Alarm | Yes | ||
| Power Failure Alarm | Yes | ||
| Overload Alarm | Yes | ||
| Low Battery Alarm | Yes | ||
| Â | Â | ||
| Power Management Features | Â | ||
| Load Banks | (3) Individually Controllable Load Banks | ||
| Remote Load Shedding | Yes – With Network Management | ||
| Remote Equipment Reboot | Yes – With Network Management | ||
| Automatic Voltage Regulation | Yes | ||
| Hot-Swappable Batteries | Yes | ||
| Extended Runtime | Yes | ||
| Remote Management | Optional | ||
| Surge / Noise Protection | Yes | ||
| Energy Efficiency | 97% at Full Load in AC Mode | ||
| Â | Â | ||
| Physical | Â | ||
| Primary Form Factor | Rackmount | ||
| Rack Height | 2U | ||
| Housing Material | Steel | ||
| Cooling Method | Fan | ||
| Height | 3.43 in (87 mm) | ||
| Width | 17.3 in (439 mm) | ||
| Depth | 19.4 in (493 mm) | ||
| Unit Weight | 60 lb (27.22 kg) | ||
| Minimum Required Rack Depth | 23 in (58.42 cm) | ||
| Minimum Rack Depth without External Battery Pack | 22.5 in (57 cm) | ||
| Minimum Rack Depth with External Battery Pack | 26.5 in (67 cm) | ||
| Included Rack Mounting | 4-Post 19-inch Rackmount Hardware | ||
| Included Rack Range | 20.5–36 in (521–914 mm) | ||
| Optional 2-Post Mounting | 2POSTRMKITWM | ||
| Optional Tower Installation | 2-9USTAND | ||
| Optional Short-Depth Rack Mounting | 4POSTRAILKITWM | ||
| Optional Front-Rail Mounting | UPSHDEARKIT | ||
| Â | Â | ||
| Environmental | Â | ||
| Operating Temperature | 32–104°F (0–40°C) | ||
| Storage Temperature | 5–122°F (-15–50°C) | ||
| Relative Humidity | 0–95%, Non-Condensing | ||
| AC Mode Heat Dissipation – Full Load | 152 BTU/hr | ||
| Battery Mode Heat Dissipation – Full Load | 546 BTU/hr | ||
| AC Mode Efficiency – Full Load | 97% | ||
| Audible Noise | 45 dBA Maximum at 1 Meter | ||
| Â | Â | ||
| Surge Protection & Filtering | Â | ||
| Surge Suppression Rating | 570 Joules | ||
| Surge Suppression Response Time | Instantaneous | ||
| EMI/RFI Noise Suppression | Yes | ||
| Â | Â | ||
| Conformance | Â | ||
| Product Certifications | CSA (Canada) | ||
| Â | NOM (Mexico) | ||
| Â | UL 1778 | ||
| Product Compliance | RoHS | ||
| Â | FCC Part 15 Class A (USA) | ||
| Â | Â | ||
| Condition & Warranty | Â | ||
| Condition | Refurbished UPS | ||
| Batteries | New Batteries Installed | ||
| Network Card | Not Included – Optional | ||
| Warranty | 1 Year Full Replacement Warranty |