Tripp Lite SmartOnline 3000VA 2700W RM 2U 120V
Model: SU3000RTXL2U
Input:Â NEMAÂ L5-30P (120V - 30A)
Output: (6) 5-15/20R, (1) L5-30R
Double Conversion Online UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included
Back Order
Love Manufacturer: Tripp Lite
Model: Tripp Lite SmartOnline UPS 3000VA 2700W, RM, 2U, 30A, 120V, New Batteries, Refurbished UPS
Condition: New batteries, refurbished UPS
Part Number: SU3000RTXL2U
Maximum output: 2700W / 3000VA
Typical backup time at half load: 13.8 minutes (1350 Watts)
Typical backup time at full load: 4.8 minutes (2700 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartOnline 3000VA 2700W Tower 120V SU3000RTXL2U Manual
SU3000RTXL2U - Tripp Lite SmartOnline 3000VA Specifications:
Input:
|
Rated input current (Maximum Load) |
24A maximum |
||
|
Nominal Input Voltage(s) Supported |
120V AC |
||
|
UPS Input Connection Type |
|
||
|
Recommended Electrical Service |
30A 120V |
||
|
Input Phase |
Single-Phase |
||
|
Input Cord Length (ft.) |
10 |
||
|
Input Cord Length (m) |
3.05 |
Output:
|
Output Volt Amp Capacity (VA) |
3000 |
||||
|
Output kVA Capacity (kVA) |
3 |
||||
|
Output Watt Capacity (Watts) |
2700 |
||||
|
Output kW Capacity (kW) |
2.70 |
||||
|
Power Factor |
0.9 |
||||
|
Crest Factor |
3:1 |
||||
|
Nominal Voltage Details |
120V default |
||||
|
Frequency Compatibility |
50 / 60 Hz |
||||
|
Frequency Compatibility Details |
Accepts 40 to 70Hz input frequency. Output frequency matches input nominal on startup, defaults to 60 Hz on coldstart. Frequency conversion from 60 to 50 Hz -or- 50 to 60 Hz supported. Output capacity de-rates to 70% of |
||||
|
Output Voltage Regulation (Line Mode) |
+/- 2% |
||||
|
Output Voltage Regulation (Economy Line Mode) |
+/- 10% |
||||
|
Output Voltage Regulation (Battery Mode) |
+/- 2% |
||||
|
Load Management Receptacles |
Two switchable three-outlet load banks |
||||
|
Output Circuit Breakers |
20A (x2) - each breaker protects 3 5-15/20R outlets, L5-30R outlet is un-breakered |
||||
|
Output AC Waveform (AC Mode) |
Pure Sine wave |
||||
|
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||||
|
Output Capacity Details |
INVERTER SHORT-CIRCUIT PROTECTION: Inverter short-circuit protection is electrically protected; OVERLOAD |
||||
|
Nominal Output Voltage(s) Supported |
100V; 110V; 115V; 120V; 127V |
||||
|
Output Receptacles |
|
||||
|
Individually Controllable Load Banks |
Yes |
Battery:
|
Full Load Runtime (min.) |
4.8 min. (2700w) |
|
Half Load Runtime (min.) |
13.8 min. (1350w) |
|
Expandable Battery Runtime |
Supports extended runtime with optional external battery packs |
|
External Battery Pack Compatibility |
BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible) |
|
DC System Voltage (VDC) |
72 |
|
Battery Recharge Rate (Included Batteries) |
Less than 8.1 hours from 10% to 90% (typical, full load discharge) |
|
Internal UPS Replacement Battery |
See RBC selector guide (replacement battery part number is also labeled on the internal battery door) |
|
Battery Access |
Front panel battery access door |
|
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
|
Expandable Runtime |
Yes |
Voltage Regulation:
|
Voltage Regulation Description |
Online, double-conversion power conditioning |
|
Overvoltage Correction |
ONLINE MODE: 2% output voltage regulation during overvoltages to 150 |
|
Undervoltage Correction |
2% output voltage regulation during undervoltages to 80V (66-100% load) |
|
Severe Undervoltage Correction |
2% output voltage regulation during undervoltages to 70V (33-66% load) or 60V (under 33% load) |
User Interface, Alerts & Controls:
|
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
|
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch |
|
Audible Alarm |
Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation |
|
LED Indicators |
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats |
Surge / Noise Suppression:
|
UPS AC Suppression Joule Rating |
504 |
|
EMI / RFI AC Noise Suppression |
Yes |
|
AC Suppression Response Time |
Instantaneous |
Physical:
|
Cooling Method |
Fan
|
|
Included Mounting Accessory |
Includes 4 post rackmount installation accessories
|
|
Installation Form Factors Supported |
2 post rackmount ( 2POSTRMKITWM ); Tower ( 2-9USTAND )
|
|
Minimum Required Rack Depth with |
77
|
|
Minimum Required Rack Depth with |
30.25
|
|
Minimum Required Rack Depth |
74
|
|
Minimum Required Rack Depth |
29.25
|
|
Primary Form Factor |
Rackmount
|
|
Primary UPS Depth (mm) |
616
|
|
Primary UPS Height (mm) |
88 |
|
Primary UPS Width (mm) |
438 |
|
Rack Height |
2U |
|
Shipping Dimensions (hwd / cm) |
24.00 x 59.99 x 76.00 |
|
Shipping Dimensions (hwd / in.) |
9.45 x 23.62 x 29.92 |
|
Shipping Weight (kg) |
39.46 |
|
Shipping Weight (lbs.) |
87.00 |
|
UPS Housing Material |
Steel |
|
UPS Power Module Dimensions (hwd, cm) |
8.79 x 43.79 x 61.60 |
|
UPS Power Module Dimensions (hwd, in.) |
3.46 x 17.24 x 24.25 |
|
UPS Power Module Weight (kg) |
31.17 |
|
UPS Power Module Weight (lbs.) |
68.72 |
Environmental:
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
|
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius. |
|
Relative Humidity |
5 to 95%, non-condensing |
|
AC Mode BTU / Hr. (Full Load) |
531 |
|
AC Economy Mode BTU / Hr. (Full Load) |
484.5 |
|
Battery Mode BTU / Hr. (Full Load) |
1037 |
|
AC Economy Mode Efficiency Rating (100% Load) |
95% |
|
Audible Noise |
50 dBA max, front-side @ 1m |
Communications:
|
Network Management Cards |
WEBCARDLX |
|
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications |
|
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports and modify the UPS Power Strategy settings download PowerAlert Local software at http://www.tripplite.com/poweralert |
|
Communications Cable |
USB and DB9 cabling included |
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
Communications Interface |
Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |