Liebert GXT4 UPS 1500VA 1350W Double Conversion RM 2U 230V GXT4-1500RT230 - Refurbished

Liebert GXT4 UPS 1500VA 1350W RM/Tower 2U 230V
Model: GXT4-1500RT230
Input: IEC 60320 C14 (230V AC)
Output: (6) IEC 60320 C13
Maximum Output: 1500VA / 1350W
Online Double-Conversion UPS - Pure Sine Wave Output
Zero Transfer Time & Extended Runtime Support
Compatible with GXT4-48VBATT External Battery Cabinets
New Batteries, Refurbished UPS
1 Year Full Replacement Warranty Included

In stock

Manufacturer: Vertiv / Liebert
Model: Liebert GXT4 1500VA 1350W Online UPS, Rack/Tower, 230V
Part Number: GXT4-1500RT230
Maximum Output: 1350W / 1500VA
Topology: Online Double-Conversion UPS
Form Factor: Rack/Tower, 2U
Input: IEC 60320 C14
Output: (6) IEC 60320 C13
Output Voltage: 200V / 208V / 220V / 230V / 240V selectable
Output Waveform: Sine Wave
Typical Backup Time at Half Load: 18 minutes
Typical Backup Time at Full Load: 6 minutes
Battery: (4) 12V / 9Ah VRLA batteries
External Battery Support: Yes — GXT4-48VBATT, up to 6 external battery packs
Communications: USB, RS-232, terminal-block communication & Liebert IntelliSlot
Condition: New Batteries, Refurbished UPS
Warranty: 1 Year Full Replacement Warranty

Description: The Vertiv Liebert GXT4-1500RT230 is a 1500VA / 1350W online double-conversion UPS designed to provide continuous, clean sine-wave power for servers, network equipment, telecommunications systems, and other sensitive electronics. This 2U rack/tower UPS features selectable 200V / 208V / 220V / 230V / 240V output, (6) IEC C13 outlets, an LCD display for local monitoring and configuration, programmable outlet groups, USB and RS-232 communications, a Liebert IntelliSlot port for optional network management, and support for GXT4-48VBATT external battery cabinets for extended runtime. Refurbished with new batteries and backed by a 1 Year Full Replacement Warranty.


 

 

Liebert GXT4 1500VA 1350W Online UPS  GXT4-1500RT230 - User's Manual

 

 


GXT4-1500RT230 - Liebert GXT4 1500VA 1350W Online UPS Specifications:

Key Features  
Manufacturer  Vertiv / Liebert
Model GXT4-1500RT230
Product Series Liebert GXT4
UPS Topology Online Double-Conversion
Form Factor Rack / Tower Convertible
Rack Height 2U
Rated Power Capacity 1500VA / 1350W
Output Power Factor 0.9
Nominal Input Voltage 230V AC
Nominal Output Voltage 230V AC
Selectable Output Voltage 200V / 208V / 220V / 230V / 240V
Input Connection IEC 60320 C14
Output Connections (6) IEC 60320 C13
Output Waveform Sine Wave
Transfer Time 0 ms (Online Mode)
External Battery Support Yes
Compatible External Battery Cabinet GXT4-48VBATT
Maximum External Battery Cabinets Up to 6
User Interface LCD Display
Communication Slot Liebert IntelliSlot
Condition New Batteries, Refurbished UPS
Warranty 1 Year Full Replacement Warranty
   
Input  
Nominal Input Voltage 230V AC
Input Voltage Range 176–288V AC at Full Load
Input Voltage Range at Reduced Load 100–288V AC
Input Frequency 40–70 Hz
Input Frequency Sensing Auto-Sensing
Input Connection IEC 60320 C14
Input Phase Single-Phase
Input Power Factor ≥0.99 at Full Load
Input Circuit Breaker Yes
Generator Compatible Yes
   
Output  
Output Capacity 1500VA
Maximum Output Power 1350W
Output Power Factor 0.9
Nominal Output Voltage 230V AC
User-Selectable Output Voltage 200V / 208V / 220V / 230V / 240V
Output Receptacles (6) IEC 60320 C13
Output Frequency 50 / 60 Hz
Frequency Regulation ±0.1 Hz
Output Waveform Sine Wave
Voltage Regulation ±1%
Transfer Time 0 ms
Programmable Output Receptacles Yes
Output Groups 3 Groups
Always-On Outlet Group 1 Group
Programmable Outlet Groups 2 Groups
Frequency Converter Mode Supported
Active ECO Mode Supported
Dynamic Bypass Supported
   
Battery & Runtime  
Battery Type Valve-Regulated, Non-Spillable Lead-Acid (VRLA)
Internal Battery Quantity (4)
Battery Rating 12V / 9Ah Each
Battery System Voltage 48V DC
Typical Runtime @ 50% Load 18 Minutes
Typical Runtime @ 100% Load 6 Minutes
External Battery Support Yes
External Battery Cabinet GXT4-48VBATT
Maximum External Battery Cabinets Up to 6
Runtime with 1 External Battery Cabinet @ 50% Load Approx. 79 Minutes
Runtime with 1 External Battery Cabinet @ 100% Load Approx. 31 Minutes
Hot-Swappable Batteries Yes
User-Replaceable Batteries Yes
Battery Test Automatic / Manual
Cold Start Supported
Battery Recharge Automatic
Deep Discharge Protection Supported
   
Communications & Management  
Front Panel Interface LCD Display with Control Buttons
Local UPS Monitoring Supported
USB Port Yes
RS-232 Serial Port Yes
Terminal Block Communication Yes
Communication Expansion Slot Liebert IntelliSlot
Network Management Supported with Optional IntelliSlot Network Card
SNMP Management Supported with Compatible Optional Network Card
Web-Based Management Supported with Compatible Optional Network Card
Remote UPS Monitoring Supported with Optional Network Card
Remote Shutdown Supported
Programmable Outlet Control Supported
Emergency Power Off (EPO) Supported through Terminal Block
Battery Monitoring Supported
Load Monitoring Supported
Event / Alarm Monitoring Supported
   
User Interface, Alerts & Controls  
Display Type LCD
UPS Status Display Supported
Load Level Display Supported
Battery Status Display Supported
Input / Output Information Supported
Operating Mode Display Supported
Configuration through LCD Supported
Audible Alarm Yes
On-Battery Alarm Yes
Low-Battery Alarm Yes
Overload Alarm Yes
UPS Fault Alarm Yes
Bypass Status Displayed
Battery Test Control Supported
Output Voltage Configuration Supported
External Battery Cabinet Configuration Supported
   
Operating Modes  
Online / Mains Mode Supported
Battery Mode Supported
Bypass Mode Supported
Battery Recharge Mode Supported
Active ECO Mode Supported
Frequency Converter Mode Supported
Dynamic Bypass Automatic
   
Physical  
Form Factor Rack / Tower Convertible
Rack Height 2U
Housing Metal
Cooling Fan-Cooled
Dimensions (D × W × H) 19.6 × 16.9 × 3.3 in (497 × 430 × 85 mm)
Net Weight Approx. 51.8 lb (23.5 kg)
Rack Installation Supported
Tower Installation Supported
External Battery Connection Rear Panel
   
Environmental  
Operating Temperature 32°F to 104°F (0°C to 40°C)
Recommended Temperature for Battery Life 32°F to 77°F (0°C to 25°C)
Relative Humidity 0–95%, Non-Condensing
Operating Elevation Up to 10,000 ft (3,000 m) at 25°C without Derating
Storage Elevation Up to 50,000 ft (15,000 m)
Audible Noise – Front / Side <45 dBA at 1 m
Audible Noise – Rear <46 dBA at 1 m
   
Agency & Compliance  
Safety IEC / EN / AS 62040-1:2008
Safety Mark GS
RFI / EMI IEC / EN / AS 62040-2, Category C2
EMC Classification CISPR22 Class A
Surge Immunity IEC / EN 62040-2 / IEC / EN 61000-4-5
Transportation ISTA Procedure 1A