Vertiv Liebert GXT5 1500VA 1350W RM 2U 120V, RDU101 Intellislot Communications Card Pre-Installed
Model: GXT5-1500LVRT2UXLN
Input:Â NEMA 5-15P (120VÂ -Â 15A)
Output: (6) NEMA 5-15R
Double-Conversion Online UPS - Sine wave Output
New batteries, refurbished UPS
1 Year Warranty Included
In stock
Manufacturer: Vertiv, Liebert
Model: Vertiv Liebert GXT5 UPS 1500VA 1350W RM 2U 120V - Online double conversion UPS (with RDU101 Network Card)
Condition: New batteries, refurbished UPS
Part Number:Â GXT5-1500LVRT2UXLN
Maximum output: 1350W / 1500VA
Typical backup timeat half load: 18.8Â minutes (675 Watts)
Typical backup time at full load: 6.7Â minutes (1350 Watts)
Warranty: 1 year full replacement warranty
Description: Â The Vertiv Liebert GXT5-1500LVRT2UXLN is a 1500VA / 1350W online double-conversion UPS designed for critical IT systems, delivering clean sine wave power with zero transfer time. It includes (6) NEMA 5-15R outlets and a 2U rack/tower convertible design, with internal batteries providing up to 18.8 minutes of runtime at half load. Equipped with the RDU101 network card, it supports remote monitoring via SNMP and HTTPS, along with email/SMS alerts and environmental monitoring. This refurbished unit comes with new batteries and a 1-year full replacement warranty.
Â
Liebert GXT5 1500VA 1350W GXT5-1500LVRT2UXLN - User's Manual
Â
GXT5-1500LVRT2UXLN - Liebert UPS 1500VA / 1350W Specifications:
Â
Input:
|
Range |
Typical 120V |
|
Frequency |
40-70Hz; Auto Sensing |
|
Input Power Cord |
10 ft. attached w/ |
Output:
|
Output Receptacles |
|
||
|
Typical 120V |
110/115/120VAC |
||
|
Waveform |
Sine wave |
||
|
Utility (AC) Mode Overload |
>200% for 250ms; |
Battery:
|
Type |
Valve-regulated, non-spillable, lead acid |
|
Backup Time (100% Load) |
6.7 |
|
Backup Time (50% Load) |
18.8 |
|
+1 External Battery Cabinet |
32.4 |
|
+1 External Battery Cabinet |
79.7 |
Environmental Requirements:
|
Operating Temperature, °F (°C) |
+32 to +104 (0 to 40) |
|
Storage Temperature, °F (°C ) |
-4 to +140 (-20 to 60) |
|
Relative Humidity |
0% to 95%, non-condensing |
|
Operating Elevation |
10,000 ft. (3,000m) |
|
Storage Elevation |
50,000 ft. (15,000m) |
|
Audible Noise |
<Â 46dBA at 3 ft. (1m) front and side |
Physical:
|
Dimensions (inch/mm) |
16.9 x 18.5 x 3.4 (430 x 470 x 85) |
|
Weight (lbs/kg) |
46.2 (21) |
Â
Communications & Management (GXT5-1500LVRT2UXLN + RDU101):
|
Control Interface |
LCD graphical display with keypad + secure web interface (HTTPS) via RDU101 |
|
Front Panel |
Color LCD for real-time UPS status, load %, battery level, alarms, and configuration |
|
Remote Monitoring |
Full remote monitoring via embedded RDU101 network card |
|
Network Interface |
10/100 Mbps Ethernet (RJ-45) via RDU101 |
|
Communication Ports |
USB, RS-232, 1× RJ-45 Ethernet, 1× RJ-45 One-Wire (environmental sensors) |
|
Communication Slot |
IntelliSlot (occupied by RDU101 card) |
|
Supported Protocols |
SNMP v1/v2c/v3, Modbus TCP/IP, HTTP/HTTPS, SMTP |
|
Web Access |
Secure HTTPS access (Chrome, Firefox, Safari, Edge compatible) |
|
Remote Shutdown |
Supported via network (graceful shutdown agents/software) |
|
Software Integration |
Vertiv Power Insight, Trellis Enterprise, LIFE Services |
|
Alarm Notifications |
Email and SMS alerts |
|
Alarm Types |
Power failure, low battery, overload, temperature, system faults |
|
Notifications |
SNMP traps, email alerts, SMS (gateway dependent) |
|
Environmental Monitoring |
Supported via Liebert SN sensors (temperature, humidity, leak, door status) |
|
Sensor Interface |
One-Wire port (RJ-45) for external environmental sensors |
|
Data Logging |
Event logs, alarm history, power conditions, environmental data |
|
Firmware Upgrade |
Remote firmware/config updates via HTTPS or HTTP API |
|
Security |
HTTPS encryption, SNMPv3 (MD5/SHA, DES/AES), certificate support |
|
Authentication |
RADIUS, TACACS+, LDAP/Active Directory, Kerberos |
|
User Access Control |
Role-based multi-user access control |
|
File Transfer |
High-speed firmware/config upload via web interface |
|
Emergency Power Off (EPO) |
Supported (hardware port on UPS) |
Â
Agency:
|
Surge Immunity |
ANSI C62.41 Category B |
|
Transportation |
ISTA Procedure 1A |
|
Safety |
UL 1778 4th Edition and CSA |
|
Emissions |
FCC Part 15 (Class A) - |
|
Environmental |
WEEE and ROHS2 REACH |
Â